What: /sys/class/accel/accel<n>/device/armcp_kernel_ver
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Version of the Linux kernel running on the device's CPU.
Will be DEPRECATED in Linux kernel version 5.10, and be
replaced with cpucp_kernel_ver
What: /sys/class/accel/accel<n>/device/armcp_ver
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Version of the application running on the device's CPU
Will be DEPRECATED in Linux kernel version 5.10, and be
replaced with cpucp_ver
What: /sys/class/accel/accel<n>/device/clk_max_freq_mhz
Date: Jun 2019
KernelVersion: 5.7
Contact: [email protected]
Description: Allows the user to set the maximum clock frequency, in MHz.
The device clock might be set to lower value than the maximum.
The user should read the clk_cur_freq_mhz to see the actual
frequency value of the device clock. This property is valid
only for the Gaudi ASIC family
What: /sys/class/accel/accel<n>/device/clk_cur_freq_mhz
Date: Jun 2019
KernelVersion: 5.7
Contact: [email protected]
Description: Displays the current frequency, in MHz, of the device clock.
This property is valid only for the Gaudi ASIC family
What: /sys/class/accel/accel<n>/device/cpld_ver
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Version of the Device's CPLD F/W
What: /sys/class/accel/accel<n>/device/cpucp_kernel_ver
Date: Oct 2020
KernelVersion: 5.10
Contact: [email protected]
Description: Version of the Linux kernel running on the device's CPU
What: /sys/class/accel/accel<n>/device/cpucp_ver
Date: Oct 2020
KernelVersion: 5.10
Contact: [email protected]
Description: Version of the application running on the device's CPU
What: /sys/class/accel/accel<n>/device/device_type
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Displays the code name of the device according to its type.
The supported values are: "GOYA"
What: /sys/class/accel/accel<n>/device/eeprom
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: A binary file attribute that contains the contents of the
on-board EEPROM
What: /sys/class/accel/accel<n>/device/fuse_ver
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Displays the device's version from the eFuse
What: /sys/class/accel/accel<n>/device/fw_os_ver
Date: Dec 2021
KernelVersion: 5.18
Contact: [email protected]
Description: Version of the firmware OS running on the device's CPU
What: /sys/class/accel/accel<n>/device/hard_reset
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Interface to trigger a hard-reset operation for the device.
Hard-reset will reset ALL internal components of the device
except for the PCI interface and the internal PLLs
What: /sys/class/accel/accel<n>/device/hard_reset_cnt
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Displays how many times the device have undergone a hard-reset
operation since the driver was loaded
What: /sys/class/accel/accel<n>/device/high_pll
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Allows the user to set the maximum clock frequency for MME, TPC
and IC when the power management profile is set to "automatic".
This property is valid only for the Goya ASIC family
What: /sys/class/accel/accel<n>/device/ic_clk
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Allows the user to set the maximum clock frequency, in Hz, of
the Interconnect fabric. Writes to this parameter affect the
device only when the power management profile is set to "manual"
mode. The device IC clock might be set to lower value than the
maximum. The user should read the ic_clk_curr to see the actual
frequency value of the IC. This property is valid only for the
Goya ASIC family
What: /sys/class/accel/accel<n>/device/ic_clk_curr
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Displays the current clock frequency, in Hz, of the Interconnect
fabric. This property is valid only for the Goya ASIC family
What: /sys/class/accel/accel<n>/device/infineon_ver
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Version of the Device's power supply F/W code. Relevant only to GOYA and GAUDI
What: /sys/class/accel/accel<n>/device/max_power
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Allows the user to set the maximum power consumption of the
device in milliwatts.
What: /sys/class/accel/accel<n>/device/mme_clk
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Allows the user to set the maximum clock frequency, in Hz, of
the MME compute engine. Writes to this parameter affect the
device only when the power management profile is set to "manual"
mode. The device MME clock might be set to lower value than the
maximum. The user should read the mme_clk_curr to see the actual
frequency value of the MME. This property is valid only for the
Goya ASIC family
What: /sys/class/accel/accel<n>/device/mme_clk_curr
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Displays the current clock frequency, in Hz, of the MME compute
engine. This property is valid only for the Goya ASIC family
What: /sys/class/accel/accel<n>/device/module_id
Date: Nov 2023
KernelVersion: not yet upstreamed
Contact: [email protected]
Description: Displays the device's module id
What: /sys/class/accel/accel<n>/device/parent_device
Date: Nov 2023
KernelVersion: 6.8
Contact: [email protected]
Description: Displays the name of the parent device of the accel device
What: /sys/class/accel/accel<n>/device/pci_addr
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Displays the PCI address of the device. This is needed so the
user would be able to open a device based on its PCI address
What: /sys/class/accel/accel<n>/device/pm_mng_profile
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Power management profile. Values are "auto", "manual". In "auto"
mode, the driver will set the maximum clock frequency to a high
value when a user-space process opens the device's file (unless
it was already opened by another process). The driver will set
the max clock frequency to a low value when there are no user
processes that are opened on the device's file. In "manual"
mode, the user sets the maximum clock frequency by writing to
ic_clk, mme_clk and tpc_clk. This property is valid only for
the Goya ASIC family
What: /sys/class/accel/accel<n>/device/preboot_btl_ver
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Version of the device's preboot F/W code
What: /sys/class/accel/accel<n>/device/security_enabled
Date: Oct 2022
KernelVersion: 6.1
Contact: [email protected]
Description: Displays the device's security status
What: /sys/class/accel/accel<n>/device/soft_reset
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Interface to trigger a soft-reset operation for the device.
Soft-reset will reset only the compute and DMA engines of the
device
What: /sys/class/accel/accel<n>/device/soft_reset_cnt
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Displays how many times the device have undergone a soft-reset
operation since the driver was loaded
What: /sys/class/accel/accel<n>/device/status
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Status of the card:
* "operational" - Device is available for work.
* "in reset" - Device is going through reset, will be
available shortly.
* "disabled" - Device is not usable.
* "needs reset" - Device is not usable until a hard reset
is initiated.
* "in device creation" - Device is not available yet, as it
is still initializing.
* "in reset after device release" - Device is going through
a compute-reset which is executed after a device release
(relevant for Gaudi2 only).
What: /sys/class/accel/accel<n>/device/thermal_ver
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Version of the Device's thermal daemon
What: /sys/class/accel/accel<n>/device/tpc_clk
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Allows the user to set the maximum clock frequency, in Hz, of
the TPC compute engines. Writes to this parameter affect the
device only when the power management profile is set to "manual"
mode. The device TPC clock might be set to lower value than the
maximum. The user should read the tpc_clk_curr to see the actual
frequency value of the TPC. This property is valid only for
Goya ASIC family
What: /sys/class/accel/accel<n>/device/tpc_clk_curr
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Displays the current clock frequency, in Hz, of the TPC compute
engines. This property is valid only for the Goya ASIC family
What: /sys/class/accel/accel<n>/device/uboot_ver
Date: Jan 2019
KernelVersion: 5.1
Contact: [email protected]
Description: Version of the u-boot running on the device's CPU
What: /sys/class/accel/accel<n>/device/vrm_ver
Date: Jan 2022
KernelVersion: 5.17
Contact: [email protected]
Description: Version of the Device's Voltage Regulator Monitor F/W code. N/A to GOYA and GAUDI