Freescale MPC512x LocalPlus Bus FIFO (called SCLPC in the Reference Manual)
Required properties:
- compatible: should be "fsl,mpc512x-lpbfifo";
- reg: should contain the offset and length of SCLPC register set;
- interrupts: should contain the interrupt specifier for SCLPC; syntax of an
interrupt client node is described in interrupt-controller/interrupts.txt;
- dmas: should contain the DMA specifier for SCLPC as described at
dma/dma.txt and dma/mpc512x-dma.txt;
- dma-names: should be "rx-tx";
Example:
sclpc@10100 {
compatible = "fsl,mpc512x-lpbfifo";
reg = <0x10100 0x50>;
interrupts = <7 0x8>;
dmas = <&dma0 26>;
dma-names = "rx-tx";
};